Poland Market
Home > Product > Geography Oriented > Poland Market
  • MD36DA-C EV 6mA DC Leakage Protection Type A RCD Reaidual Current Detector with Self-test Function
  • MD36DA-C EV 6mA DC Leakage Protection Type A RCD Reaidual Current Detector with Self-test Function
  • MD36DA-C EV 6mA DC Leakage Protection Type A RCD Reaidual Current Detector with Self-test Function
  • MD36DA-C EV 6mA DC Leakage Protection Type A RCD Reaidual Current Detector with Self-test Function

MD36DA-C EV 6mA DC Leakage Protection Type A RCD Reaidual Current Detector with Self-test Function

Share :
Product parameters

Product Details

MD36DA-C is a high sensitivity RDC-MD dc leakage current sesnor also colled residual current monitor(RCM) and residual current device(RCD) intended for the detection of DC residual currents at 6mA or greater in 50Hz/60Hz AC installations. This DC RCD detect smooth DC and half-wave DC currents.

The dc rcd is a compact solution designed to be cable mounted. When a DC leakage current of 3~6mA is detected, an alarm signal is output. It can judge whether the sensor is in a normal working state in real time through the self-test function. It is primarily intended for use in EV charging stations to output alarm signal under a DC residual fault current condition. It may also be used to detect DC residual currents in DC, single phase or multiphase installations.

IVY MD series residual current sensors are optimized for fast, low-cost assembly, combined with the highest product and production quality. In addition to the use of charging piles. Also suitable for electro-medical instruments, ventilation systems, inverters, UPS, escalators, welding equipment, smart home, industrial machines, elevators, IOT, photovoltaic systems etc. There is a DC component leakage scenario. Provide more reliable protection. Protecting personal and electrical equipment safety.


MD36DA-C Cost-effective RCD Solution 3-6mA DC Leakage Alarm EV Residual Current Sensor


Product Advantages

DC 2~15mA micro current detection

DC 3~6mA Alarm (Needn’t Set)

Self-test Function, Open Collector Alarm Output

Integrated Design, Cable/Horizontal Type Installation

Compared Type B RCCB, More Costly


Product Parameters

Voltage

12V±20% (Current about 12mA)

Current

DC current 2~15mA

Alarm Current Range

DC 3~6mA

Alarm Output

Open Collector

Operation Temperature Range

-25~+80℃

Installation

Cable/Horizontal Type

Appearance

Plastic casing V0


Product Applications 


MD0630T01A EN 61008 EN 62955 Type A RCD 6mA DC Leakage Sensors for EV Charging Station

1.Being able to detect smooth DC residual currents which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and of the installation

2.can guarantee dependable protection for field technicians and installed machinery by detecting high frequency residual current and protecting against smooth DC residual currents in the event of a fault.

3.can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of order can cause discomfort.

4.In installation where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures and interruption of any critical operation