Slovenia Market
Home > Product > Geography Oriented > Slovenia Market
  • MD36DA-P IEC62752 Type AC/A/F/B RDC-DD 6mA DC Differential Current Monitoring RCM for AC Wallbox
  • MD36DA-P IEC62752 Type AC/A/F/B RDC-DD 6mA DC Differential Current Monitoring RCM for AC Wallbox
  • MD36DA-P IEC62752 Type AC/A/F/B RDC-DD 6mA DC Differential Current Monitoring RCM for AC Wallbox

MD36DA-P IEC62752 Type AC/A/F/B RDC-DD 6mA DC Differential Current Monitoring RCM for AC Wallbox

Share :
Product parameters

Product Details

MD36DA-P is a high sensitivity RDC-DD/RDC-MD/RDC-PD dc leakage current sesnor also colled residual current monitor(RCM) and residual current device(RCD) intended for the detection of DC residual currents at 6mA or greater in 50Hz/60Hz AC installations. This dc rcd detect smooth DC and half-wave DC currents.

The dc rcm/rdc-dd is a compact solution designed to be PCB mounted. When a DC leakage current of 3~6mA is detected, an alarm signal is output. It can judge whether the sensor is in a normal working state in real time through the self-test function. It is primarily intended for use in EV charging stations to output alarm signal under a DC residual fault current condition. It may also be used to detect DC residual currents in DC, single phase or multiphase installations.

IVY MD series residual current sensors are optimized for fast, low-cost assembly, combined with the highest product and production quality. In addition to the use of charging piles. Also suitable for electro-medical instruments, inverters, UPS, welding equipment, smart home, industrial machines, elevators, IOT, photovoltaic systems etc. There is a DC component leakage scenario. Provide more reliable protection. Protecting personal and electrical equipment safety.

MD36DA-P IEC62752 Pin Type RCD Protection EV 6mA DC Leakage Sensor with Open Collector Output


Product Advantages

DC 2~15mA micro current detection

DC 3~6mA Alarm (Needn’t Set)

Self-test Function, Open Collector Alarm Output

Integrated Design, PCB/Vertical Type Installation

Comply with IEC62752 Standard

Various types of Leakage Current Detection(Type AC/F/A/B)


Product Parameters

image.png


Product Applications 

1.Being able to detect smooth DC residual currents which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and of the installation

2.can guarantee dependable protection for field technicians and installed machinery by detecting high frequency residual current and protecting against smooth DC residual currents in the event of a fault.

3.can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of order can cause discomfort.

4.In installation where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures and interruption of any critical operation