Product Introduction
IVY offers MD0630T01A for monitoring and/or providing shock protection and fault protection on AC and DC installations and for EV charging applications. MD0630T01A is a built-in RCD specifically developed for EV-charging providing all-current sensitivity. The RCD device can issues alarm signal in case of hazardous electrical faults (DC and AC). It has the characteristics of accurate measurement, small size and integration. The RCD sensor can be set separately for AC and DC leakage and has a digital output function. MD0630T01A is an automotive grade leakage current sensor from IVY also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, earth leakage detector and fault current sensor. Multiple types leakage current detection(AC/A/F/B/B+), with two separate fault signal outputs – one Pin for Type A 30 mA & DC 6 mA leakage current detection and the other Pin for solely DC 6 mA leakage current detection. It can be used for built-in RCD / RDC-DD at AC charging stations to meet IEC 61851-1 & IEC 60364-7-722.
Product Description
This product is fully compliant with TUV/CE-EMC
The MD0630T01A is a residual current monitor intended for the detection of DC and AC residual currents in 50Hz/60Hz AC installations.
The MD0630T01A is primarily intended for use in Mode 2 Electric Vehicle In-Cable Control and Protection Devices (IC-CPDs) and Mode 3 Wallbox Charger, to disconnect the supply to the Electric Vehicle under an AC or DC residual current fault condition.
The MD0630T01A may also be used to detect DC or AC residual currents in DC, single phase or multiphase installations.
The MD0630T01A is a compact solution designed to be mounted directly onto a PCB.
Product Features
1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955
2. Small Size; Integration Design; Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional
4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output
5. UART Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019
6. Certification: TUV(IEC62955/IEC62752/IEC61851-1/IEC62196); UL2231-1/UL2231-2; IS17017; CE-EMC
7. Type B RCD/RCM for EV Charger Protection; Electrical Safety at Low Cost (Compared to Type B RCCB)
8. Robust Mechanical and Electrical Design for Harsh Environmental Conditions
EV Charging Standard
Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy : at 25℃, DC±0,2mA, AC±0.3mA
Can read current value and set alarm current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package
Typical Application
Ground fault current detection
Solar inverter residual current
Converter leakage current detection
UPS and other power ground fault detection
Electric vehicle charging station
Single or 3 Phases differential current detection
Indusrtrail Automation, Smart Home, IOT Field, Power Distribution Cabinet