Product Details
MD0630T41A is a cable&pcb mount AC DC leakage current sensor, which can also be called residual current sensor, residual current monitor (RCM), residual current device (RCD), differential current sensor, leakage current detector, fault current sensor etc. This residual current monitor will detect DC and AC residual currents in 50Hz/60Hz AC installations according to IEC62955. It's primarily intended for use in Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition. It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs.
In electric vehicle charging if the DC fault current is greater than 6mA, it could change the characteristics of a Type A RCD due to its core saturation, resulting in the type A failing to trip and a lack of detection of the DC fault. In this instance, the risk of electric shock is increased, and safety is compromised. IVY has launched a new RCD sensor that is designed to detect a DC earth fault, which is more cost-effective than using a Type B RCCB. In the event of a dangerous electrical fault, the sensor will output an alarm signal (by setting the leakage alarm value). This new RCD sensor enables compliance with the updated IEC62955:2018 and reduces the cost of developing electric vehicle charging solutions.
IVY MD series residual current sensors are optimized for fast, low-cost assembly, combined with the highest product and production quality. MD series residual current sensor (RCD/RCM) is an ideal protection device, for the detection and protection of different leakage currents/residual currents/fault currents. The RCD could quickly output alarm signal when people get an electric shock or leakage current exceeds stipulated value, protecting personal and electrical equipment safety.
Product Advantages
Small Size, Flexible, Integration Design, Residual current range 2~100 mA
Switching output for 6 mA DC/30 mA (IEC) or 5 mA /20 mA (UL 2231)
Digital Output, Measurement resolution DC 0.2 mA AC 0.3mA
Full load current up to 200A (1-phase) or 150A (3-phase)
AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs
Robust mechanical design suitable for harsh electronic environments
Total system cost significantly reduced compared to type B RCCB
With UART Comm Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy: at 25℃, DC±0,2mA, AC±0.3mA
Can read current value and set alarm current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package
Product Applications
By using a IVY MD series RCD sensor integrated into an IC-CPD or wall box, customers can save the high costs of installing a type B RCCB to provide all-current sensitivity and electrical safety at low cost. As the residual currents to be monitored only occur in the event of electrical faults and are extremely low (mA), maximum measurement precision is critical. In addition, a fast response time is required to maintain safety features.