UK Market
Home > Product > Geography Oriented > UK Market
  • MD0630T01A-2 IEC 61008 Ultra-small Internal RCD 6mA DC Earth Leakage Protection Sensor for Portable Charger
  • MD0630T01A-2 IEC 61008 Ultra-small Internal RCD 6mA DC Earth Leakage Protection Sensor for Portable Charger
  • MD0630T01A-2 IEC 61008 Ultra-small Internal RCD 6mA DC Earth Leakage Protection Sensor for Portable Charger
  • MD0630T01A-2 IEC 61008 Ultra-small Internal RCD 6mA DC Earth Leakage Protection Sensor for Portable Charger

MD0630T01A-2 IEC 61008 Ultra-small Internal RCD 6mA DC Earth Leakage Protection Sensor for Portable Charger

Share :
Product parameters

Product Introduction

MD0630T01A-2 is an automotive grade ultra-small leakage current sensor designed for portable charger also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, earth leakage detector and differential current sensor. Dedicated to detect to Type AC, A, F, B and B+ leakage current measurement. The internal parts of the portable charger should be as small as possible, our new leakage detector is small and lightweight, which just meets this requirement. This residual current monitor will detect DC and AC residual currents in 50Hz/60Hz AC installations according to IEC62955. It's primarily intended for use in Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition. It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs.


In electric vehicle charging if the DC fault current is greater than 6mA, it could change the characteristics of a Type A RCD due to its core saturation, resulting in the type A failing to trip and a lack of detection of the DC fault. In this instance, the risk of electric shock is increased, and safety is compromised. IVY has launched a new 6mA DC sensor that is designed to detect a DC earth fault, which is more cost-effective than using a Type B RCCB. In the event of a dangerous electrical fault, the sensor will output an alarm signal (by setting the leakage alarm value). This new 6mA DC sensor enables compliance with the updated IEC62955:2018 and reduces the cost of developing electric vehicle charging solutions.


MD0630T01A-2 Ultra-small PCB/Pin Type Leakage Detector AC DC Residual Current Sensor for Portable Charger


Product Advantages

Ultra-small, Flexible, Integration Design, Residual current range 2~100 mA

Switching output for 6 mA DC/30 mA (IEC) or 5 mA /20 mA (UL 2231)

Error(Fault) output (Integrated self-monitoring and test functions)

Digital Output, Measurement resolution DC 0.2 mA AC 0.3mA

Full load current up to 200A (1-phase) or 150A (3-phase)

AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs

Robust mechanical design suitable for harsh electronic environments

Total system cost significantly reduced compared to type B RCCB

With UART Comm Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019


MD0630T01A-2 Small AC DC Residual Current Detector RCD Leakage Sensor for Portable 16A IC-CPD Device


Product Parameters

Wide voltage input: 12V±20%

Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

Accuracy : at 25℃, DC±0,2mA, AC±0.3mA

Installation: PCB/Pin/Vertical Type

Three outputs: DC alarm, AC alarm, AC/DC alarm

Working environment temperature: -25℃~+80℃

Appearance: Plastic case, small SIP package


EV Charging Applications 

MD0630T01A-2 Portable AC DC RCD Sensor Residual Current Protection Device for 3phase AC Type 2 Charger