  • MD0630T41A-1 EV RCM 6mA DC Ground Fault Protection Leakage Sensor Residual Current Device
  • MD0630T41A-1 EV RCM 6mA DC Ground Fault Protection Leakage Sensor Residual Current Device
  • MD0630T41A-1 EV RCM 6mA DC Ground Fault Protection Leakage Sensor Residual Current Device

MD0630T41A-1 EV RCM 6mA DC Ground Fault Protection Leakage Sensor Residual Current Device

Share :
Product parameters

Product Details

MD0630T41A-1 is an AC DC leakage sensor (residual current sensor) for EV charging station. It has the characteristics of high sensitivity, correct measurement, small size and compact/integration design. The residual current sensor can be set separately for AC and DC leakage. When the set current is reached, an alarm signal is generated, and the switch control signal is output at the same time. 

MD0630T41A-1 is a residual current monitor intended for the detection of DC and AC residual currents in 50Hz/60Hz AC installations. The Residual Current Monitor (RCM) range is intended for the detection of DC and/or AC residual currents in AC or DC installations. These RCMs are ideally suited for use with Electric Vehicle charging cables (Mode 2 Protection) and EV charging stations (Mode 3 Protection). Residual current detection options for IEC based requirements are 30mA AC or 6mA DC or both, and are 20mA AC & 6mA DC for UL requirements.

AS a Type B RCD/RCM, MD series leakage sensor have numerous applications and are suitable for many industries including electric vehicle charging, photovoltaic systems (solar panels), industrial device, medical device, new energy, DC screen, fire distribution cabinet, IOT field and any installation where there is a risk of DC current flowing. It is the technology that brings us closest to total protection for all known residual fault currents.


MD0630T41A-1 6mA DC Residual Current Detector Type B Leakage Sensor for Mode 3 AC Charger


Product Feature

1. DC 2-15mA, AC 3-100mA, Alarm Output: DC 6mA AC 30mA

2. Small Volume, Integration Design, Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional

3. Leakage Protection Device, Digital Output and Detection of Fault and Leakage Current

4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs

5. URAT Comm. with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019

6. Professional Certification IEC 62955/IEC 62752/IEC 61851-1; UL 2231-1/UL 2231-2; TUV; CE-EMC Certified

7. Widely Application for 1/3 phase 16A/32A AC Charger and DC Charger (Mode 2/Mode 3/Mode 4 Protection)


Product Parameters

Wide voltage input: 12V±20%

Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

Accuracy class: at 25℃, DC±0,2mA, AC±0.3mA

Working environment temperature: -25℃~+80℃

Installation: Cable Type

Plastic casing: SIP encapsulation


Typical Application

Charging mode 2

IC-CPD in charging cables for electric vehicles (EV) and plug-in hybrid electric vehicles (PHEV)

Charging mode 3

Wallboxes for charging EV and PHEV

Charging piles for charging EV and PHEV